DF-C Series AC INDUSTRIAL POWER SUPPLIES

Maximum values of the series:3kVrms L-N / 3kA per phase / 1MVA / ØPL = 0.30€/W

Output phases:1 / 3 Three-phase currentDisplay accuracy I:±0.5% FS + 5 dig
Voltage range:0 … 300 Vrms L-N / 0 … 520 Vrms L-L
(0 … 3 kVrms L-N)*
Display accuracy P:±0.5% FS + 5 dig
Current range:0 ... 1260A LV** / 0 ... 630A FS**
(0 ... 3kA L-N)*
Display accuracy F:±0.5% + 5 digits
Frequency range:47Hz … 63Hz
/ 100Hz* / 200Hz*
(See DF-CM series for higher frequencies)
Setting accuracy U±1% FS
Power range:0 ... 1MVASetting accuracy F:±0.1% FS
Cabinet:Stand-alone RackExt. control analogue:Yes*
Regulation:UExt. feedback analogue:Yes*
Load regulation U:≤1%RS232:Yes*
Mains regulation U:≤1%RS485:Yes*
Frequency stability:≤0.1%FSRS422:No
Voltage stability:±1%Open protocol:Yes*
Harmonic distortion:≤2%Modbus RTU:Yes*
Crest Factor:≤2%SCPI:No
Recovery Time (50% change):≤15msInterlock:Yes*
Display accuracy U:±0.5% FS + 5 digExt. output On/Off Ctrl..:Yes*
Output phases:1 / 3 Three-phase current
Voltage range:0 … 300 Vrms L-N
0 … 520 Vrms L-L
(0 … 3 kVrms L-N)*
Current range:0 ... 1260A LV**
0 ... 630A FS**
(0 ... 3kA L-N)*
Frequency range: 47Hz … 63Hz
/ 100Hz* / 200Hz*
(See DF-CM series for higher frequencies)
Power range:0 ... 1MVA
Cabinet:Stand-alone Rack
Regulation:U
Load regulation U:≤1%
Mains regulation U:≤1%
Frequency stability:≤0.1% FS
Voltage stability:±1%
Harmonic distortion:≤2%
Crest Factor:≤2%
Recovery Time (50% change):≤15ms
Display accuracy U:±0.5% FS + 5 dig
Display accuracy I:±0.5% FS + 5 dig
Display accuracy P:±0.5% FS + 5 dig
Display accuracy F:±0.5% + 5 digits
Setting accuracy U±1% FS
Setting accuracy F:±0.1% FS
Ext. control analogue:Yes*
Ext. feedback analogue:Yes*
RS232:Yes*
RS485:Yes*
RS422:No
Open protocol:Yes*
Modbus RTU:Yes*
SCPI:No
Interlock:Yes*
Ext. output On/Off Ctrl..:Yes*

* Optional
* LV = high voltage range 0 - 150Vrms L-N / FS = high voltage range 0 - 300Vrms L-N

Developed for particularly power-intensive applications in laboratories and industry, AC industrial power supply units of the DF-C series offer performance up to the megawatt range, completely maintenance-free, even with continuous use around the clock. Switchable voltage / current ranges (LV heavy current 0 ... 150Vrms L-N) or (FS high voltage 0 ... 300Vrms L-N) make the AC power supply particularly versatile. These AC industrial power supplies offer excellent frequency and voltage stability as well as a clean sine wave. In addition, it is possible to expand and adapt the range of functions.

Additional options

The following is a brief description of the additional options for AC industrial power supplies of the DF-C series. A detailed description can be found in the data sheet of the series. If you have any questions, please contact our support during our opening hours via live chat or by e-mail and we will be happy to help you.

[U] Ext. analogue control U
Input for external control of the output voltage via an analogue control signal.

[F] Ext. analogue feedback output U
Returns the actual value of the output voltage.

[G] Ext. analogue feedback output I
Returns the actual value of the output current.

[A] Interlock & Ext. Output On/Off Ctrl.
Input for controlling the status of the output of the laboratory power supply unit (On/Off), optionally switchable as "Interlock" or external control.

[D] Digital connection
Digital connection for setting and reading out the unit parameters in real time via an open protocol.

[O] Galvanic isolation
The output of the basic version of the DF-C series devices has a potential to PE (is grounded), which complies with standard safety regulations. All devices can also be ordered as potential-free versions or potential-free versions with residual current circuit breakers. For details, please refer to the data sheet.

ModelPriceOutput typeOutput voltageOutput current 0 ... 150Vrms L-NOutput current 0 ... 300Vrms L-NPowerOutput frequencyDisplay resolution FDisplay resolution UDisplay resolution IDisplay resolution PVoltage stabilityFrequency stabilityHarmonic distortionCrest factorLoad regulation ULoad regulation ILine regulation ULine regulation I
DF-C6112023.070,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 1.1kA0 ... 545A0 ... 120kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6345079.810,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 1.26kA0 ... 630A0 ... 450kVA47Hz ... 63Hz0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6115026.580,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 1.36kA0 ... 682A0 ... 150kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6350088.930,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 1.38kA0 ... 695A0 ... 500kVA47Hz ... 63Hz0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6360092.720,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 1.66kA0 ... 833A0 ... 600kVA47Hz ... 63Hz0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6120034.680,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 1.81kA0 ... 909A0 ... 200kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C634512.120,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 126A0 ... 63A0 ... 45kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C61155.980,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 136A0 ... 68A0 ... 15kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63065.090,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 16.8A0 ... 8.4A0 ... 6kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C636014.520,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 168A0 ... 84A0 ... 60kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C61206.730,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 180A0 ... 90A0 ... 20kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63750105.640,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 2.08kA0 ... 1.04kA0 ... 750kVA47Hz ... 63Hz0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6125042.410,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 2.27kA0 ... 1.13kA0 ... 250kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV1A0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C631000127.160,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 2.77kA0 ... 1.38kA0 ... 1MVA47Hz ... 63Hz0.01Hz100mV1A0.1kW±1%≤2%≤2%≤1%≤1%
DF-C637517.340,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 226A0 ... 113A0 ... 75kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C61308.420,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 270A0 ... 135A0 ... 30kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C639019.190,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 272A0 ... 136A0 ... 90kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6310020.960,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 276A0 ... 138A0 ... 100kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63105.850,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 28A0 ... 14A0 ... 10kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6312023.900,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 364A0 ... 182A0 ... 120kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C614511.010,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 408A0 ... 204A0 ... 45kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6315030.090,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 416A0 ... 208A0 ... 150kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63156.700,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 42A0 ... 21A0 ... 15kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C615011.620,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 454A0 ... 227A0 ... 50kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C61053.380,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 45A0 ... 22.5A0 ... 5kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C616013.230,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 540A0 ... 270A0 ... 60kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6318040.080,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 546A0 ... 273A0 ... 180kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C61063.620,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 54A0 ... 27A0 ... 6kW47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6320045.050,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 556A0 ... 278A0 ... 200kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63207.470,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 58A0 ... 29A0 ... 20kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C617516.970,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 682A0 ... 341A0 ... 75kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6325050.740,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 757A0 ... 378A0 ... 250kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63033.940,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 8.4A0 ... 4.2A0 ... 3kVA47Hz ... 63Hz0.01Hz100mV1mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C619018.820,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 818A0 ... 409A0 ... 90kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6330056.900,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 834A0 ... 417A0 ... 300kVA47Hz ... 63Hz0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C63308.980,00 Variable AC true sine wave 3 phases0 ... 300Vrms L-N0 ... 84A0 ... 42A0 ... 30kVA47Hz ... 63Hz0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C61105.240,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 90A0 ... 45A0 ... 10kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.01kW±1%≤0.1% FS≤2%≤2%≤1%≤1%
DF-C6110020.230,00 Variable AC true sine wave 1 phase0 ... 300Vrms L-N0 ... 910A0 ... 455A0 ... 100kVA47Hz ... 63Hz, 100Hz, 200Hz, 400Hz (max. 50% power)0.01Hz100mV100mA0.1kW±1%≤0.1% FS≤2%≤2%≤1%≤1%