DP-S Series COMPACT LABORATORY POWER SUPPLIES

Maximum values of the series: 800V / 200A / 6kW / ØPL = 0.82€/W

Voltage range:0 ... 800VSetting accuracy U:±0.5% reading ± 2 dig
Current range:0 ... 200ASetting accuracy I:±1% reading ± 2 dig
Power range:0 ... 6kWExt. control analogue:Yes*
Cabinet:Table-top unitExt. feedback analogue:No
Regulation:U / IRS232:No
Load regulation U:≤0.5% + 2 digRS485:No
Load regulation I:≤0.5% + 2 digRS422:No
Mains regulation U:≤0.2% + 2 digOpen protocol:-
Line regulation I:≤0.5% + 2 digModbus RTU:-
Noise U:≤1%FS (rms)SCPI:-
Noise I:≤1%FS (rms)Reverse current protection:Yes*
Recovery Time (50% change): Polarity changer:No
Display accuracy U:±1%FS ± 1 digInterlockYes*
Display accuracy I:±1%FS ± 1 digExt. output On/Off Ctrl.Yes*
Voltage range:0 ... 800V
Current range:0 ... 200A
Power range:0 ... 6kW
Cabinet:Table-top unit
Regulation:U / I
Load regulation U:≤0.5% + 2 dig
Load regulation I:≤0.5% + 2 dig
Mains regulation U:≤0.2% + 2 dig
Line regulation I:≤0.5% + 2 dig
Noise U:≤1%FS (rms)
Noise I:≤1%FS (rms)
Recovery Time (50% change): 
Display accuracy U:±1%FS ± 1 dig
Display accuracy I:±1%FS ± 1 dig
Setting accuracy U:±0.5% reading ± 2 dig
Setting accuracy I:±1% reading ± 2 dig
Ext. control analogue:Yes*
Ext. feedback analogue:No
RS232:No
RS485:No
RS422:No
Open protocol:-
Modbus RTU:-
SCPI:-
Reverse current protection:Yes*
Polarity changer:No
InterlockYes*
Ext. output On/Off Ctrl.Yes*

* Optional

The compact laboratory power supplies of the DP-S series form the entry level of our high-performance power supplies and offer excellent performance and reliability in a compact cabinet, designed as a tabletop unit with transport handle. Ideal for high power applications such as load testing of inverters, heating elements, charging of accumulators or capacitor banks. The compact laboratory power supply of the DP-S series can also be used in industrial processes up to 4kW continuous load completely maintenance-free.

Brief summary of the advantages of DP-S series high-performance power supply units:

ConnectivityOptional analogue control of output voltage and current via 0 ... 10V, 0 ... 5V or 4 ... 20mA signals. Optional interlock loop 5V.
FeaturesOutput values 0 ... 100% variably adjustable, operating modes constant voltage and constant current with automatic switching depending on the load.
Output configurationOutput floating, short-circuit-proof, can be operated constantly in short-circuit mode.
SecurityAutomatic shutdown in case of overheating, overvoltage, overcurrent.
Upgrade optionsPartially compatible with AP series expansion modules.

*Optional

Up to 6kW power in the size of a shoe box

High performance and yet compact

Image shows a DP-S laboratory power supply, details may vary for your unit depending on the revision, for the most up to date information please check the "data sheet" tab.

Units of the DP-S series were developed especially for applications in the field of "testing and repair", where high power must be available for a short time and a stationary high-performance power supply unit is not always available at the place of use or is simply not needed for cost reasons. Despite the specialisation, laboratory power supplies of the DP-S series are also used in production as well as in the laboratory – and have been used successfully for years (according to our customers).

DP-S series duty-cycle

The maximum power available depends on the model – see "Data sheet".

Laboratory power supplies of the DP-S series are designed for high short-term power and can provide up to and including 4.5kW continuously, above that for at least one hour. The laboratory power supply is equipped with smart temperature control so that when the power exceeds 4.5kW, the power supply automatically switches off the output when a critical temperature is reached and switches to "cool-down" mode until a normal internal temperature is reached. The current status of the power supply unit is indicated by an LED on the front panel.

High performance, sturdy equipment

Despite the compact design, compact laboratory power supplies of the DP-S series are very reliable and stable at high power. Current and voltage are controlled with a precise analogue circuit with fast response time and the output is floating on all models. In addition, laboratory power supplies of the DP-S series have two precise rotary controls for rough and precision adjustment of voltage and current.

Four-digit LED display

Current and voltage are shown on two bright four-digit LED displays on the front. Status information such as possible errors (overvoltage, overcurrent, temperature) can be read via coloured LEDs.

External control

Laboratory power supplies of the DP-S series can optionally be equipped with analogue external control inputs for output voltage and current and an interlock input. The control inputs are floating and offer high precision through the use of high-quality signal converters. All analogue connections are accessible via a shielded safety plug on the front of the unit, so that it is not necessary to reach to the rear to make the connection.

Compatible with many external expansion modules of the AP series

Expand your laboratory power supply of the DP-S series with additional functions – even after purchase.

Image shows a DP-M series high-performance power supply unit in 2U cabinet with AP8 module (top).

DP-S series power supplies are compatible with many optional AP series expansion modules, so you are no longer limited to the configuration you choose when ordering, but you can also expand certain functions at a later date using external modules. In addition, the AP series is constantly being expanded and maintained with new modules, so that you can also expand existing units in the future with new functions that we will introduce.

Currently, the following AP series expansion modules are compatible with DP-S series laboratory power supplies:

Model AP9: Combined reverse current protection (inductive and capacitive loads).
Depending on the maximum voltage and current, the module is manufactured in a 19″ 1U 1/2, 2U or 3U cabinet and protects your power supply unit against reverse currents, which can occur when operating with large capacitive or inductive loads. This means that you do not need an additional protective circuit between the power supply unit and your load, which reduces complexity enormously.

Model AP8: Additional EMC filter with capacitance on the output side.
Some loads require a cleaner voltage than the power supply can deliver in the basic configuration, or the inverse, generate very strong interferences (e.g. by high-frequency current draw with very steep edges - square wave). This can influence the control of the power supply at high currents. For these cases we have developed the AP8 module which combines a three-stage EMC filter with a large fast capacitance to further stabilise the output voltage of the power supply in critical applications on the one hand and to protect the power supply from the influence of loads on the other. This combination guarantees a stable output voltage even under the highest load from complex high-frequency loads.

Versatile verso

Optional analogue inputs and heavy-current coupling with strain-relief (units over 2500W)

Image shows a DP-S laboratory power supply, details such as the position of the connections may differ on your unit depending on the version.

Portable laboratory power supplies of the DP-S series are designed for high performance with maximum mobility, while a powerful cooling system ensures low temperatures even under high load. The mains connections are either designed as C19 / C20 sockets / plugs or as high-voltage couplings with strain-relief. 3-phase supply has been omitted to ensure maximum flexibility for outdoor applications, so that power supply units with a maximum power of 6 kW can also be operated on only one phase with a fuse protection of 32A. The analogue control signals (optional) are connected at the front via a shielded DIN socket, a suitable plug is included in the delivery.

Interlock input (optional)

By adding the interlock function to the power supply unit, the output of the power supply unit can be blocked under certain conditions instantly. An example application would be to block the output of the power supply unit when the protective cover of a machine connected to the power supply unit is open. Furthermore, the interlock input can be used to switch the output of the power supply unit on or off remotely by first switching the output on manually and then enabling or blocking it via the interlock signal. On DP-S series laboratory power supplies, the interlock input is designed as a floating loop which blocks the output of the power supply in the event of an interruption – the option designation is A1.

Analogue external remote control of the output voltage (optional)

If your application requires an analogue connection and remote control of the output voltage of the power supply unit, an analogue control input (2-pin) can be realised with option U via the DIN connector on the front. The standards 0 ... 10V (U1), 0 ... 5V (U2) and 4 ... 20mA (U3) are available for the control.

Analogue external remote control of the output current (optional)

Option L adds a control input (2-pin) to the power supply unit via the DIN connector on the front which enables analogue external remote control of the output current of the power supply unit. The standards 0 ... 10V (L1), 0 ... 5V (L2) and 4 ... 20mA (L3) are available for the control.

ModelPriceOutput voltageOutput currentPowerDisplay resolution UDisplay resolution IResidual ripple UResidual ripple ILoad regulation ULoad regulation ILine regulation ULine regulation I
DP1H-10S860,00 0 ... 100V0 ... 10A0 ... 1kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP1H-20S1.070,00 0 ... 100V0 ... 20A0 ... 2kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP1H-30S1.330,00 0 ... 100V0 ... 30A0 ... 3kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP1H-50S1.730,00 0 ... 100V0 ... 50A0 ... 5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP1H-5S760,00 0 ... 100V0 ... 5A0 ... 500W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP1H-60S1.950,00 0 ... 100V0 ... 60A0 ... 6kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP120-10S900,00 0 ... 120V0 ... 10A0 ... 1.2kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP120-20S1.070,00 0 ... 120V0 ... 20A0 ... 2.4kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP120-30S1.490,00 0 ... 120V0 ... 30A0 ... 3.6kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP120-40S1.680,00 0 ... 120V0 ... 40A0 ... 4.8kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP120-50S1.950,00 0 ... 120V0 ... 50A0 ... 6kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP120-5S780,00 0 ... 120V0 ... 5A0 ... 600W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP150-10S940,00 0 ... 150V0 ... 10A0 ... 1.5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP150-20S1.350,00 0 ... 150V0 ... 20A0 ... 3kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP150-30S1.650,00 0 ... 150V0 ... 30A0 ... 4.5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP150-3S760,00 0 ... 150V0 ... 3A0 ... 450W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP150-40S1.950,00 0 ... 150V0 ... 40A0 ... 6kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP150-5S800,00 0 ... 150V0 ... 5A0 ... 750W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-1HS990,00 0 ... 15V0 ... 100A0 ... 1.5kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-120S1.110,00 0 ... 15V0 ... 120A0 ... 1.8kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-150S1.240,00 0 ... 15V0 ... 150A0 ... 2.25kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-2HS1.410,00 0 ... 15V0 ... 200A0 ... 3kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-30S740,00 0 ... 15V0 ... 30A0 ... 450W10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-50S790,00 0 ... 15V0 ... 50A0 ... 750W10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-60S820,00 0 ... 15V0 ... 60A0 ... 900W10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP15-80S880,00 0 ... 15V0 ... 80A0 ... 1.2kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP2H-10S1.100,00 0 ... 200V0 ... 10A0 ... 2kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP2H-1S730,00 0 ... 200V0 ... 1A0 ... 200W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP2H-20S1.560,00 0 ... 200V0 ... 20A0 ... 4kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP2H-2S760,00 0 ... 200V0 ... 2A0 ... 400W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP2H-3S810,00 0 ... 200V0 ... 3A0 ... 600W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP2H-5S880,00 0 ... 200V0 ... 5A0 ... 1kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP220-1S730,00 0 ... 220V0 ... 1A0 ... 220W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP220-2S780,00 0 ... 220V0 ... 2A0 ... 440W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP220-3S830,00 0 ... 220V0 ... 3A0 ... 660W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP250-10S1.230,00 0 ... 250V0 ... 10A0 ... 2.5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP250-1S740,00 0 ... 250V0 ... 1A0 ... 250W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP250-20S1.770,00 0 ... 250V0 ... 20A0 ... 5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP250-2S800,00 0 ... 250V0 ... 2A0 ... 500W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP250-3S840,00 0 ... 250V0 ... 3A0 ... 750W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP250-5S950,00 0 ... 250V0 ... 5A0 ... 1.25kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-10S1.470,00 0 ... 300V0 ... 10A0 ... 3kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-15S1.680,00 0 ... 300V0 ... 15A0 ... 4.5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-1S760,00 0 ... 300V0 ... 1A0 ... 300W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-20S2.000,00 0 ... 300V0 ... 20A0 ... 6kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-2S820,00 0 ... 300V0 ... 2A0 ... 600W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-3S890,00 0 ... 300V0 ... 3A0 ... 900W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP3H-5S990,00 0 ... 300V0 ... 5A0 ... 1.5kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-1HS1.350,00 0 ... 30V0 ... 100A0 ... 3kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-150S1.680,00 0 ... 30V0 ... 150A0 ... 4.5kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-2HS1.950,00 0 ... 30V0 ... 200A0 ... 6kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-20S750,00 0 ... 30V0 ... 20A0 ... 600W10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-30S820,00 0 ... 30V0 ... 30A0 ... 900W10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-40S880,00 0 ... 30V0 ... 40A0 ... 1.2kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-50S930,00 0 ... 30V0 ... 50A0 ... 1.5kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-60S1.010,00 0 ... 30V0 ... 60A0 ... 1.8kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP30-80S1.160,00 0 ... 30V0 ... 80A0 ... 2.4kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP4H-10S1.720,00 0 ... 400V0 ... 10A0 ... 4kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP4H-1S810,00 0 ... 400V0 ... 1A0 ... 400W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP4H-2S880,00 0 ... 400V0 ... 2A0 ... 800W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP4H-3S950,00 0 ... 400V0 ... 3A0 ... 1.2kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP4H-5S1.130,00 0 ... 400V0 ... 5A0 ... 2kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP5H-10S1.880,00 0 ... 500V0 ... 10A0 ... 5kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP5H-1S850,00 0 ... 500V0 ... 1A0 ... 500W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP5H-2S950,00 0 ... 500V0 ... 2A0 ... 1kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP5H-3S1.050,00 0 ... 500V0 ... 3A0 ... 1.5kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP5H-5S1.280,00 0 ... 500V0 ... 5A0 ... 2.5kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP50-1HS1.730,00 0 ... 50V0 ... 100A0 ... 5kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP50-20S830,00 0 ... 50V0 ... 20A0 ... 1kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP50-30S930,00 0 ... 50V0 ... 30A0 ... 1.5kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP50-50S1.210,00 0 ... 50V0 ... 50A0 ... 2.5kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP50-60S1.330,00 0 ... 50V0 ... 60A0 ... 3kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP50-80S1.570,00 0 ... 50V0 ... 80A0 ... 4kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP6H-1S890,00 0 ... 600V0 ... 1A0 ... 600W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP6H-2S950,00 0 ... 600V0 ... 2A0 ... 1.2kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP6H-3S1.170,00 0 ... 600V0 ... 3A0 ... 1.8kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP6H-5S1.490,00 0 ... 600V0 ... 5A0 ... 3kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-1HS1.980,00 0 ... 60V0 ... 100A0 ... 6kW10mV100mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-10S770,00 0 ... 60V0 ... 10A0 ... 600W10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-20S870,00 0 ... 60V0 ... 20A0 ... 1.2kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-30S1.000,00 0 ... 60V0 ... 30A0 ... 1.8kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-50S1.330,00 0 ... 60V0 ... 50A0 ... 3kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-60S1.490,00 0 ... 60V0 ... 60A0 ... 3.6kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP60-80S1.680,00 0 ... 60V0 ... 80A0 ... 4.8kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP8H-1S970,00 0 ... 800V0 ... 1A0 ... 800W100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP8H-2S1.150,00 0 ... 800V0 ... 2A0 ... 1.6kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP8H-3S1.290,00 0 ... 800V0 ... 3A0 ... 2.4kW100mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP8H-5S1.760,00 0 ... 800V0 ... 5A0 ... 4kW100mV1mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP80-20S980,00 0 ... 80V0 ... 20A0 ... 1.6kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP80-30S1.170,00 0 ... 80V0 ... 30A0 ... 2.4kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP80-50S1.530,00 0 ... 80V0 ... 50A0 ... 4kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig
DP80-60S1.680,00 0 ... 80V0 ... 60A0 ... 4.8kW10mV10mA≤1%FS (rms)≤1%FS (rms)≤0.5% + 2 dig≤0.5% + 2 dig≤0.2% + 2 dig≤0.5% + 2 dig